As an experienced security CMS website operator, I know that the stable operation of the website is the foundation for the efficient publication and optimization of content.The choice of deployment and process management methods for systems like AnQiCMS, which are developed based on the Go language, directly affects the reliability and operational efficiency of the system.Today, let's delve into the similarities and differences between the PID monitoring mechanism of AnQiCMS's Go project and the manual maintenance script when deployed on Baota panel.
Go project process management: Baota panel PID monitoring and two manual script paths
The 'Go project' feature of Baota panel is an integrated service designed to simplify the deployment and management of Go applications.When we add a Go project through the Baota panel, the panel is responsible for starting our AnQiCMS executable file and monitoring its process.This monitoring mechanism is usually based on the process ID (PID).The panel records the PID generated after AnQiCMS starts and checks if the PID exists periodically.Once the associated PID disappears, the panel will attempt to restart the AnQiCMS service automatically according to the preset rules to ensure the continuity of the service.This method encapsulates the process management work inside the panel, providing operation personnel with one-click start, stop, and restart operation buttons, greatly simplifying daily maintenance.
In contrast, manual script management provides a more fundamental and flexible control method. According to the AnQiCMS documentation, projects usually providestart.shandstop.shThis is an example script. Itstart.shFor example, this type of script will check for the existence of the AnQiCMS process usingps -ef | grep '\<anqicms\>'etc. commands. If the process does not exist, it will executenohup $BINPATH/$BINNAME >> $BINPATH/running.log 2>&1 &The command to start AnQiCMS, and run it in the background, while redirecting the output to the log file.stop.shIt is responsible for finding and terminating the corresponding PID. In this way, the logic for process startup, shutdown, status check, and error recovery is all written and controlled by us.
The convenience and limitations of Baota panel PID monitoring
The Go project PID monitoring of Baota panel provides significant convenience.Firstly, it is highly automated, and we can start or stop the AnQiCMS service simply by clicking buttons on the panel interface.When AnQiCMS crashes out due to internal errors, the panel's monitoring mechanism can quickly detect and attempt to restart automatically, providing a fundamental guarantee for the continuous availability of the service and reducing the need for manual intervention.In addition, all operations are concentrated in the Baota panel's visual interface, reducing reliance on command line operations, and is very user-friendly for operation personnel unfamiliar with Linux commands.The panel usually also provides a view of the project operation log, which is convenient for us to preliminarily troubleshoot problems.
However, this convenience is also accompanied by certain limitations.The PID monitoring of Baota panel usually only checks for the existence of process IDs.This means that if the AnQiCMS application itself becomes僵死 due to deadlock, resource exhaustion, or other complex logical errors (i.e., the application no longer responds to requests, but its process ID still exists), the Baota panel may not recognize this "false death" state and will not trigger automatic restart.At this time, the service is running on the surface, but in fact, it is unable to provide services to the outside world and requires manual intervention.Additionally, the configuration options of the Baota panel are relatively fixed, and we cannot add complex pre-processing or post-processing logic to the startup or shutdown process of AnQiCMS, such as checking the database connection before startup or performing data synchronization before shutdown.This "black box" management method is not up to the task when fine control or custom fault recovery strategies are needed.
The powerful control and operation and maintenance cost of manual script management
Manual script management gives us unparalleled control over the AnQiCMS process lifecycle. Bystart.shandstop.shScript, we can not only implement basic start and stop, but also customize complex O&M logic according to actual needs. For example, you canstart.shadd health check logic such ascurl -f http://localhost:8001/healthConfirm that AnQiCMS not only starts up but also can normally respond to HTTP requests and avoid the "false death" situation.If the health check fails, the script can implement more advanced recovery strategies such as multiple retries, delayed restarts, and sending alert notifications.systemdorsupervisordIn Linux service manager, implement system-level boot-up and more stable daemon process function.The advantage of this method lies in its high customizability and cross-platform nature, regardless of whether it is on the Baota panel, other control panels, or a pure command-line environment, as long as the Linux environment supports shell scripts, our process management logic can be universally applicable.
However, this powerful control also brings higher operation and maintenance costs.Writing and maintaining scripts requires us to have a certain knowledge of Linux command line and Shell script programming, and it requires time to write, test, and debug the script.The update and iteration of scripts require manual operation. When managing multiple AnQiCMS instances, each instance needs to maintain a set of independent scripts or manage through parameterized scripts, which undoubtedly increases complexity.Lack of a unified visual interface means that we cannot view and manage process status as intuitively as in the Baota panel, usually requiring SSH connection to the server and executing commands to complete.Once a script encounters an error, it may cause the service to fail to start or stop normally, even triggering other system issues, which requires higher skills from operations personnel.
When to choose what management method?
Whether to choose PID monitoring of Baota panel or manual script management mainly depends on your specific needs, team skills, and requirements for service reliability.
ForPersonal blog, small enterprise website or AnQiCMS deployment for non-core businessThe tolerance for service interruption is high, and with limited team operation and maintenance experience, the "Go project" function of Baota panel is undoubtedly the better choice.It provides sufficient automation and convenience to meet the basic process management needs, reducing the operation and maintenance threshold.
And forHigh availability requirements for AnQiCMS services, need fine-grained control or have complex deployment environments for enterprise-level applicationsFor example, multi-site platforms carrying important business traffic, scenarios requiring deep integration with other systems, manual script management, and combiningsystemdorsupervisordThis professional service management tool will be a more reliable choice.It allows us to implement customized health checks, fault recovery, resource isolation, and alert mechanisms, thereby building a more robust and reliable AnQiCMS operating environment.
In summary, the PID monitoring of Baota panel isconvenient and efficientrepresentative, suitable for those who pursue simple and rapid deployment; manual script management isflexible and powerfulThe embodiment, providing infinite possibilities for an operations team pursuing ultimate control and reliability.As AnQiCMS operator, we should weigh the pros and cons according to the actual situation of the project, choose the most suitable process management strategy, and ensure that AnQiCMS can continue to provide stable protection for content operation.
Frequently Asked Questions (FAQ)
1. Why is my AnQiCMS showing as running in the Baota panel Go project, but the front-end page is inaccessible?
This situation is usually that the AnQiCMS application has entered a "false death" state.This means that the Go process itself may still be running (so the Baota panel's PID monitoring thinks it is 'alive'), but the internal logic of the application has stopped responding to requests, such as a database connection failure, internal service deadlock, or memory overflow causing unresponsiveness.The Go project feature of Baota panel mainly depends on the existence of PID for monitoring and cannot detect such internal health issues.The solution is to manually restart the Go project, or consider using manual script management, and add more comprehensive health checks (such as HTTP port detection) to the script to determine if the service is truly available.
2. I can use the one I manually wrote.start.shandstop.shDo you want to use a script to replace the 'Go project' management of Baota panel?
Absolutely. In fact, for more advanced or customized deployments, many operators prefer to do so. You can upload the binary files of AnQiCMS and your customizedstart.sh/stop.shThe script is placed on the server and then used with the Linux system,crontab(such as the example of checking and starting the script every minute in the AnQiCMS document) orsystemdCome guard your AnQiCMS process.This method bypasses the Go project function of the Baota panel, providing more detailed control over the process lifecycle.start.shandstop.sh.
How to implement a graceful shutdown for my AnQiCMS Go project?
stop.shThe script can send a SIGTERM signal and wait for the AnQiCMS process to exit on its own. If it does not exit within the timeout, a SIGKILL is sent forcibly.